# Lightning Arrester 25GR 4P Type 1 for Enhanced Surge Protection

## Introduction to Lightning Arrester 25GR 4P Type 1

The Lightning Arrester 25GR 4P Type 1 is a high-performance surge protection device designed to safeguard electrical systems from lightning strikes and transient overvoltages. This robust arrester is engineered to meet the demanding requirements of industrial, commercial, and residential applications where reliable surge protection is critical.

## Key Features of 25GR 4P Type 1 Arrester

The 25GR arrester offers several advanced features that make it stand out in surge protection:

  • High discharge capacity (25kA per pole)
  • 4-pole configuration for comprehensive protection
  • Type 1 classification according to IEC standards
  • Compact and durable design
  • Visual status indication for easy maintenance

## Technical Specifications

Performance Characteristics

The 25GR 4P Type 1 lightning arrester delivers exceptional performance with:

Parameter Value
Nominal Discharge Current (In) 25kA (8/20μs)
Maximum Discharge Current (Imax) 50kA (8/20μs)
Voltage Protection Level (Up) ≤ 2.5kV
Response Time < 25ns

## Installation and Application

Where to Use the 25GR 4P Type 1 Arrester

This lightning arrester is ideal for installation in:

  • Main distribution boards
  • Industrial power systems
  • Telecommunication facilities
  • Commercial buildings
  • Critical infrastructure installations

Installation Guidelines

For optimal performance, follow these installation recommendations:

  1. Mount the arrester close to the service entrance
  2. Ensure proper grounding with low-impedance connections
  3. Use appropriate cross-section cables for connections
  4. Verify system voltage compatibility before installation

## Benefits of Choosing 25GR 4P Type 1

The 25GR arrester provides numerous advantages for surge protection:

  • Enhanced Safety: Protects equipment and personnel from dangerous voltage surges
  • System Reliability: Minimizes downtime by preventing surge-related failures
  • Cost-Effective: Reduces maintenance and replacement costs of sensitive equipment
  • Compliance: Meets international standards for surge protection devices

## Maintenance and Troubleshooting

Regular Maintenance

To ensure continued protection, perform these maintenance checks:

  • Inspect visual indicators monthly
  • Check connection tightness annually
  • Test system grounding every two years
  • Replace the arrester after a major surge event

Troubleshooting Common Issues

If you encounter problems with your 25GR arrester:

  1. Verify all connections are secure
  2. Check the status indicator for fault conditions
  3. Measure grounding resistance
  4. Consult the manufacturer’s technical support